The Unichiller 260T is an air-cooled recirculating chiller with a fixed-speed D3 pressure pump and Pilot ONE controller, rated 10–16 kW cooling between -20 and 0 °C. Within the Unichiller series it is the higher-capacity, non-variable-pump modification, intended for externally closed process loops with moderate pressure drop.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller 260T Current | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 250w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 39 l |
| Minimum fill volume | 14 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | D3 |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling capacity | 15 kW (at 0 °C) at -10 °C: 16 kW · at -20 °C: 10 kW |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Air-cooled refrigeration circuit using R-449A (A1, H280); IP20 enclosure, Class A Group 1 emissions per EN55011, intended for industrial environments.
- Fixed-speed D3 pressure pump with G1 1/4 male connections; pump speed is not adjustable, so flow is set by the external circuit's pressure drop.
- Compared with the Unichiller 110T/110Tw siblings, the 260T is the larger-capacity unit; the 'T' family shares the Pilot ONE platform, while the 'w' siblings are the lower-noise variants (65 vs 74 dB(A)).
- 39 l expansion volume with a 14 l minimum fill defines the smallest permissible loop volume.
Behavior under load and media
- Cooling capacity is ambient-dependent: 16 kW at -10 °C, 15 kW at 0 °C, 10 kW at -20 °C, valid at 20 °C room temperature; capacity falls as ambient rises.
- Temperature range -20…40 °C with 0.5 K stability at -10 °C; processes needing tighter control require a different model or control upgrade.
- Pump curve: 210 l/min at zero head, 31 l/min at 4.5 bar (max delivery pressure 4.7 bar). High-pressure-drop loops must be matched to this curve; models with 'P' in the name are the high-pressure-drop variants.
- Only for externally closed applications; open loops are not permitted.
Installation, control and operation
- 460 V 3~ 60 Hz supply; three-phase units under 63 A are delivered with cable but without plug, and external branch protection per UL 489 is required. Voltage/frequency tolerances are interdependent (-5% V with +2% Hz is not allowed).
- Pilot ONE controller with Ethernet, USB host/device and RS232; external Pt100 sensor input; power-failure response configurable as OFF/Standby, ON or Power Failure Auto.
- Process Safety mode releases maximum cooling when the overtemperature trigger is reached instead of switching off all poles.
- Indoor installation only, illuminance ≥300 lx, altitude up to 2000 m, ambient 5–40 °C; 50–200 cm wall clearance per side for maintenance; leveling feet/parking brakes must be set before start-up.
Integration & Operating Notes
Because pump speed is not adjustable, the achievable flow is determined solely by the external circuit's pressure drop: 210 l/min at zero head falls to 31 l/min at 4.5 bar. Oversized or restrictive loops will starve flow and degrade temperature stability; loops with high pressure drop should use a 'P' model instead.
The 460 V 3~ 60 Hz unit is supplied with cable but without a plug for currents under 63 A, and external branch circuit protection per UL 489 is mandatory. The installer must size and provide both from the electrical schematics, and must verify the combined voltage/frequency tolerance rule rather than voltage alone.
Air-cooled operation requires free airflow; the manual specifies 50–200 cm wall clearance on either side for maintenance, indoor use only at ≥300 lx and up to 2000 m altitude. IP20 offers no water protection, so the location must be dry and free of splashes or condensation.
The unit is designed only for externally closed applications; an open loop risks evaporation and loss of control. The 39 l expansion volume with a 14 l minimum fill sets the smallest permissible loop volume, and underfilling or overfilling degrades control or causes overflow.
The Pilot ONE can be set to OFF/Standby, ON or Power Failure Auto after a mains loss. For exothermic processes, Process Safety mode releases maximum cooling at the overtemperature trigger instead of de-energizing all poles; the correct mode must be selected and verified during commissioning.
The R-449A circuit (A1, H280) may only be serviced by approved refrigeration/air-conditioning contractors. Refrigerant charge and room volume must be checked at installation against the limit per m³ of ambient air, and cooling water supply (where applicable) must be shut off even for overnight downtimes.
Selection & Integration Q&A
Pick the 260T when the process needs 10–16 kW between -20 and 0 °C and a fixed-speed pump is acceptable. The 110T/110Tw are lower-capacity; the 'w' variants are quieter (65 vs 74 dB(A)). For high-pressure-drop loops, a 'P' model is the correct choice instead.
Mating hoses/fittings must match the G1 1/4 male pump connections, counterheld at the maximum tightening torque. Electrically, the 460 V 3~ 60 Hz unit needs a site-supplied plug (under 63 A) and UL 489 branch protection; verify the combined voltage/frequency tolerance.
Indoors only, ambient 5–40 °C, ≥300 lx, up to 2000 m altitude, with 50–200 cm clearance per side for airflow and maintenance. IP20 requires a dry location; leveling feet or parking brakes must be set before start-up, and the unit must not be placed in an ATEX zone.
The plug and branch protection are not included, and no accessories or cables are listed in the verified facts. Refrigerant-circuit service requires an approved contractor; the 50–200 cm side clearance is the maintenance access space, and the Pilot ONE interfaces (Ethernet, USB, RS232, Pt100) are built in.