Peter Huber Kältemaschinenbau Unichiller GL 250w
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau Unichiller GL 250w

Peter Huber Kältemaschinenbau Unichiller GL 250w — Recirculating chillers.

The Unichiller GL 250w is a water-cooled recirculating chiller with a Pilot ONE controller, a fixed-speed pressure pump and a 30 l expansion volume, operating from -20 to 40 °C. It is the GL variant of the Unichiller series, requiring a cooling-water supply of 1–6 bar pressure and G3/4 male connections. It serves externally closed process loops that need stable temperature control without an air-cooled condenser.

Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection

Model Pump typeSafety classTemperature range, °CPower supplyExpansion volume, m³Minimum fill volume, m³
Unichiller GL 250w Current Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller 110T C3I / NFL-10–40400V 3~ 50Hz0.007—
Unichiller 110T-H C3III / FL-10–100400V 3~ 50Hz0.007—
Unichiller 110Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 130T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 130T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 130Tw C3I / NFL-20–40400V 3~ 50Hz——
Unichiller 160T C3I / NFL-10–40400V 3~ 50Hz0.0390.014
Unichiller 160T-H C3III / FL-10–100400V 3~ 50Hz0.0390.014
Unichiller 160Tw C3I / NFL-20–40400V 3~ 50Hz0.01—
Unichiller 180-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 180T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 180T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 180Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 180Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 180w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 180w-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 200T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 200Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 210T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 210T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 210Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 230-H E1III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller 230w E1I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller 230w-H E1III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller 250T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 250T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 250Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 260T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 260T-H D3III / FL-20–100400V 3~ 50Hz0.0390.014
Unichiller 260Tw D3I / NFL-20–40400V 3~ 50Hz0.0220.015
Unichiller 260Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 300T D3I / NFL-20–40400V 3~ 50Hz0.0390.014
Unichiller 300T-H D3III / FL-20–100460V 3~ 60Hz0.0390.014
Unichiller 300Tw D3I / NFL-20–40460V 3~ 60Hz0.0220.015
Unichiller 300Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 350T D3I / NFL-20–40460V 3~ 60Hz0.0390.014
Unichiller 350Tw-H D3III / FL-20–100400V 3~ 50Hz0.0220.015
Unichiller 500Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 600Tw-H D3III / FL-20–100400V 3~ 50Hz0.007—
Unichiller 700Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller 800Tw D3I / NFL-20–40400V 3~ 50Hz0.007—
Unichiller GL 1000w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.05—
Unichiller GL 200w Pressure pump, speed notI / NFL-20–40460V 3~ 60Hz0.03—
Unichiller GL 300w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 400w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.03—
Unichiller GL 750w Pressure pump, speed notI / NFL-20–40400V 3~ 50Hz0.05—
Unichiller P180 E2I / NFL-20–40—0.0480.018
Unichiller P180-H E2III / FL-20–100400V 3~ 50Hz0.0480.018
Unichiller P180w E2I / NFL-20–40400V 3~ 50Hz0.0480.018
Unichiller P180w-H E2III / FL-20–100460V 3~ 60Hz0.0480.018
Unichiller P230 E2I / NFL-20–40460V 3~ 60Hz0.0480.018
Unichiller P230-H E2III / FL-20–100460V 3~ 60Hz0.0480.018

Full specifications

Core Performance & Functional Specifications
Expansion volume 30 l
Pump connection G1 1/4 AG male
Pump speed adjustable no
Pump type Pressure pump, speed not variable
External sensor connection Pt100
Temperature range -20...40 °C
Electrical, Power & Drive Specifications
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G3/4 male
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class I / NFL

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Cooling & Media
Cooling-water supply must deliver 1–6 bar differential pressure

The site water system must provide at least 1 bar differential pressure between inlet and outlet and must never exceed 6 bar supply pressure; undersized or overpressurized water circuits will either fail to reject rated heat or stress the condenser circuit.

Unichiller GL 250w Technical Data, page 1
Electrical
Voltage and frequency tolerances are coupled, not independent

The ±5% voltage tolerance applies only with a simultaneous ±2% frequency tolerance, and combinations such as -5% voltage with +2% frequency are explicitly not allowed; verify the site supply envelope before connection to avoid invalid warranty or malfunction.

Unichiller GL 250w Technical Data, page 2
Process Limits
Only externally closed process loops are permitted

The unit is designed for externally closed applications; open baths or loops that expose the thermal fluid to atmosphere are outside the intended use and may cause contamination or overflow.

Unichiller Operation Manual, page 34
Control & I/O
Configure power-failure response to match process restart policy

The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON or Power Failure Auto; the choice determines whether the process restarts automatically after a power outage and must be aligned with the plant's safety concept.

Unichiller Operation Manual, page 19
Control & I/O
Process Safety mode releases maximum cooling instead of tripping

In Process Safety mode the controller releases maximum cooling capacity when the overtemperature trigger value is reached, rather than switching off all poles; this is relevant for exothermic processes where cutting cooling would cause runaway temperatures.

Unichiller Operation Manual, page 18
Maintenance
Refrigerant-circuit work is restricted to approved contractors

Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors; the unit uses R-744 (A1, H280, UN 2857), so transport, handling and service procedures must follow the corresponding refrigerant safety requirements.

Unichiller Operation Manual, page 17
Maintenance
Shut off cooling water even for overnight downtime

The cooling-water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion during idle periods; this should be part of the standard shutdown procedure.

Unichiller Operation Manual, page 28
Mounting
Do not install in an ATEX zone

The unit is not explosion-protected and must not be installed or started up inside an ATEX zone; site hazardous-area classification must be checked before placement.

Unichiller Operation Manual, page 13

Selection & Integration Q&A

When should I choose the Unichiller GL 250w instead of a sibling Unichiller 110T or 110Tw model?

Choose the GL 250w when heat must be rejected to site cooling water via G3/4 connections rather than to air; the 110T/110Tw siblings are air-cooled and differ in noise level (74 dB(A) vs 65 dB(A) for Tw). The GL 250w also requires a cooling-water supply of 1–6 bar differential pressure, which the air-cooled siblings do not.

What cooling-water supply and piping must be provided for the GL 250w?

Provide cooling water at 5–20 °C inlet with at least 1 bar differential pressure and no more than 6 bar supply pressure, connected via G3/4 male fittings. The water circuit must be compatible with copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; lower water temperatures require insulating the cooling-water pipes inside the unit.

What maintenance and accessories are required beyond the base delivery?

The base delivery includes a cable but no plug for three-phase units below 63 A, and external UL 489 branch protection must be supplied by the site. Refrigerant-circuit work requires approved refrigeration contractors; the cooling-water supply must be shut off even overnight, and the unit uses R-744 (UN 2857) requiring appropriate handling procedures.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unichiller GL 250w Technical Data
Datasheet ·30,3 КБ ·2 pp.
View PDF
PDF
Unichiller Operation Manual
Manual ·2,8 МБ ·82 pp.
View PDF