Peter Huber Kältemaschinenbau Unichiller GL 250w
Peter Huber Kältemaschinenbau Unichiller GL 250w — Recirculating chillers.
The Unichiller GL 250w is a water-cooled recirculating chiller with a Pilot ONE controller, a fixed-speed pressure pump and a 30 l expansion volume, operating from -20 to 40 °C. It is the GL variant of the Unichiller series, requiring a cooling-water supply of 1–6 bar pressure and G3/4 male connections. It serves externally closed process loops that need stable temperature control without an air-cooled condenser.
Peter Huber Kältemaschinenbau Unichiller Series — Model Comparison & Selection
| Model | Pump type | Safety class | Temperature range, °C | Power supply | Expansion volume, m³ | Minimum fill volume, m³ |
|---|---|---|---|---|---|---|
| Unichiller GL 250w Current | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller 110T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 110Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 130T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 130Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | — | — |
| Unichiller 160T | C3 | I / NFL | -10–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160T-H | C3 | III / FL | -10–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 160Tw | C3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.01 | — |
| Unichiller 180-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 180Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 180Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 180w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 180w-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 200T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 200Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 210T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 210Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 230-H | E1 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w | E1 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller 230w-H | E1 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller 250T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 250Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 260T-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 260Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 260Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 300T | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.039 | 0.014 |
| Unichiller 300T-H | D3 | III / FL | -20–100 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 300Tw | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.022 | 0.015 |
| Unichiller 300Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 350T | D3 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.039 | 0.014 |
| Unichiller 350Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.022 | 0.015 |
| Unichiller 500Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 600Tw-H | D3 | III / FL | -20–100 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 700Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller 800Tw | D3 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.007 | — |
| Unichiller GL 1000w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.05 | — |
| Unichiller GL 200w | Pressure pump, speed not | I / NFL | -20–40 | 460V 3~ 60Hz | 0.03 | — |
| Unichiller GL 300w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 400w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.03 | — |
| Unichiller GL 750w | Pressure pump, speed not | I / NFL | -20–40 | 400V 3~ 50Hz | 0.05 | — |
| Unichiller P180 | E2 | I / NFL | -20–40 | — | 0.048 | 0.018 |
| Unichiller P180-H | E2 | III / FL | -20–100 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w | E2 | I / NFL | -20–40 | 400V 3~ 50Hz | 0.048 | 0.018 |
| Unichiller P180w-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230 | E2 | I / NFL | -20–40 | 460V 3~ 60Hz | 0.048 | 0.018 |
| Unichiller P230-H | E2 | III / FL | -20–100 | 460V 3~ 60Hz | 0.048 | 0.018 |
Full specifications
| Expansion volume | 30 l |
| Pump connection | G1 1/4 AG male |
| Pump speed adjustable | no |
| Pump type | Pressure pump, speed not variable |
| External sensor connection | Pt100 |
| Temperature range | -20...40 °C |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- Water-cooled condenser circuit using refrigerant R-744 (A1, H280, GWP 1, UN 2857); no air-cooled condenser, so heat is rejected to site cooling water via G3/4 male connections.
- Fixed-speed pressure pump with G1 1/4 AG male process connections; pump speed is not adjustable.
- 30 l expansion volume and Pilot ONE controller with Ethernet, USB (Host and Device) and RS232 interfaces, plus a Pt100 external sensor input.
- Sibling Unichiller 110T/110T-H/110Tw/110Tw-H models differ in noise level (74 dB(A) vs 65 dB(A) for the Tw variants); the GL 250w is distinguished by its water-cooled architecture and cooling-water interface rather than by an air-cooled fan.
Behavior under load and media
- Temperature range -20 to 40 °C; cooling capacity is rated at 20 °C room temperature, 15 °C cooling-water inlet and 1 bar differential pressure, so capacity must be derated when site water or ambient conditions deviate.
- Higher cooling-water temperature reduces cooling power and may require increased cooling-water flow rate; the water supply must be evaluated for worst-case conditions.
- The cooling-water circuit contains copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; only compatible water may be used.
- Designed for externally closed applications; models with “P” in the model name are the ones suited to high pressure-drop loops, not this GL variant.
Installation, control and operation
- Requires external branch circuit protection per UL 489; three-phase devices below 63 A are delivered with cable but without plug.
- Voltage tolerance ±5% with simultaneous frequency tolerance ±2%; certain combinations (e.g. -5% voltage with +2% frequency) are not allowed.
- Power-failure response configurable as OFF/Standby, ON or Power Failure Auto via Pilot ONE; Process Safety mode releases maximum cooling capacity when the overtemperature trigger is reached.
- Must be installed indoors at 5–40 °C ambient, IP20, illuminance at least 300 lx, altitude up to 2000 m; wall clearance 50–200 cm per side for maintenance; leveling feet/parking brakes must be set before start-up.
Integration & Operating Notes
The site water system must provide at least 1 bar differential pressure between inlet and outlet and must never exceed 6 bar supply pressure; undersized or overpressurized water circuits will either fail to reject rated heat or stress the condenser circuit.
The ±5% voltage tolerance applies only with a simultaneous ±2% frequency tolerance, and combinations such as -5% voltage with +2% frequency are explicitly not allowed; verify the site supply envelope before connection to avoid invalid warranty or malfunction.
The unit is designed for externally closed applications; open baths or loops that expose the thermal fluid to atmosphere are outside the intended use and may cause contamination or overflow.
The Pilot ONE allows the power-failure response to be set to OFF/Standby, ON or Power Failure Auto; the choice determines whether the process restarts automatically after a power outage and must be aligned with the plant's safety concept.
In Process Safety mode the controller releases maximum cooling capacity when the overtemperature trigger value is reached, rather than switching off all poles; this is relevant for exothermic processes where cutting cooling would cause runaway temperatures.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors; the unit uses R-744 (A1, H280, UN 2857), so transport, handling and service procedures must follow the corresponding refrigerant safety requirements.
The cooling-water supply must be shut off even for short downtimes such as overnight to prevent water damage and corrosion during idle periods; this should be part of the standard shutdown procedure.
The unit is not explosion-protected and must not be installed or started up inside an ATEX zone; site hazardous-area classification must be checked before placement.
Selection & Integration Q&A
Choose the GL 250w when heat must be rejected to site cooling water via G3/4 connections rather than to air; the 110T/110Tw siblings are air-cooled and differ in noise level (74 dB(A) vs 65 dB(A) for Tw). The GL 250w also requires a cooling-water supply of 1–6 bar differential pressure, which the air-cooled siblings do not.
Provide cooling water at 5–20 °C inlet with at least 1 bar differential pressure and no more than 6 bar supply pressure, connected via G3/4 male fittings. The water circuit must be compatible with copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM; lower water temperatures require insulating the cooling-water pipes inside the unit.
The base delivery includes a cable but no plug for three-phase units below 63 A, and external UL 489 branch protection must be supplied by the site. Refrigerant-circuit work requires approved refrigeration contractors; the cooling-water supply must be shut off even overnight, and the unit uses R-744 (UN 2857) requiring appropriate handling procedures.